GB 50372-2006 炼铁机械设备工程安装验收规范 (英文版)
上QQ阅读APP看本书,新人免费读10天
设备和账号都新为新人

7.13 Commissioning of Top Ignition Device

7.13.1 The commissioning of top ignition device shall meet the following requirements:

1 Manually pull the burner walking device to allow it move forward/backward,there is no obstruction during movement,nor friction with the edge of hole when passing the ignition hole.

2 Start the burner walking device to allow it move forward/backward,adjust the limit switch in accordance with the design documents.

3 Allow the burner walking device move forward/backward for at least 3 times,the operation shall be flexible without abnormal noise or vibration,the limit switch shall also operate flexibly and reliably.

Check method:observe,measure and check the commissioning records.